Loading...
 Start Page

T Patras : +30 2610 223999 / T Athens: +30 210 2751602T Thessaloniki+30 2316 019079

BFT II Analyzer
Click to enlarge
Dimensions: 20 x 30 x10 cm
Measuring channels: 2 channels
Incubation positions: 30 positions of sample incubation
Description

The BFT II Analyzer combines the advantages of mechanical and photo-optical clot-detecting principles by employing a unique turbodensitometric detection device. The semi-automated, dual-channel coagulometer is ideal for low-volume laboratories performing routine coagulation tests.

  • Light protection cap reduces the risk of user errors by keeping the pipetting channel closed unless a cuvette has been inserted
  • Pre-defined assays with stored reference curves
  • Automatic calculation of PT in sec, % of norm, INR, Fibrinogen in mg/dL or g/L
  • Dual measuring channels allow for simultaneous determinations
  • Half-volume and single cuvette testing require minimal sample volume
  • Built-in thermal printer for consolidated result handling
Features & Benefits

The BFT II Analyzer is a dual-channel coagulometer designed for the lowest volume lab. It combines the advantages of mechanical and photo-optical clot detecting principles.

Total efficiency 
  • Temperature controlled incubation block for reagents and samples
  • Sample mixing during measurement
  • Automatic result calculation, e.g., PT in sec, % of norm/ PR/ INR, Fibrinogen in mg/dL or g/L
  • Stores reference curves

Ease-of-use 

  • Light protection cap reduces the risk of user errors by keeping the pipetting channel closed unless a cuvette has been inserted
  • Built-in timer for incubation
  • Membrane keypad for easy handling of test processing
  • Pre-programmed methods 

Labor and cost savings 

  • Half-volume and single cuvette testing require minimal sample volume
  • Memory function for reference curves
  • As a back-up analyzer, the BFT II provides data comparable to those obtained with other Siemens hemostasis analyzers


Assays

PT Reagents
Dade® Innovin® INR
Dade Innovin sec
Dade Innovin %
Thromborel® S INR
Thromborel S sec
Thromborel S %

APTT Reagents
Dade Actin®
Dade Actin FS
Dade Actin FSL
Pathromtin® SL

Fibrinogen Reagents
Multifibren® U

Thrombin Time Reagents
Batroxobin Reagent1
Test Thrombin Reagent1
Thromboclotin®1
 

Factor Deficient Reagents
Factor II-Dade Innovin1
Factor II-Thromborel S1
Factor V-Dade Innovin1
Factor V-Thromborel S1
Factor VII-Dade Innovin1
Factor VII-Thromborel S1
Factor VIII-Dade Actin1
Factor VIII-Pathromtin SL1
Factor IX-Dade Actin1
Factor IX-Pathromtin SL1
Factor X-Dade Innovin1
Factor X-Thromborel S1
Factor XI-Dade Actin1
Factor XI-Pathromtin SL1
Factor XII-Dade Actin1
Factor XII-Pathromtin SL1

Lupus Anticoagulant Reagents
LA 1 Screening Reagent1
LA 2 Confirmation Reagent1


Thrombosis Risk Reagents
ProC® Globa1
ProC Global FV1
Protein C1
 

 
Technical Specifications
 
Dimensions Approx. 200 mm x 300 mm x 100 mm (W x D x H)
Weight Approx. 3.8 kg
Onboard Capacity 4 reagents including 1 reagent mixer
  Incubation block for up to 30 cuvettes
 
Throughput Approx. 60 PT tests/hour
  Approx. 30 APTT tests/hour
 
Sample Handling Manual sample pipetting
Reagent Handling Manual reagent pipetting
  4 positions GW 15 – bottles
GW5 bottles using reducer rings
 
Operation Pre-programmed methods
  2 free positions for user-defined methods
Built-in timer
Automatic timer start and stop
 

Contact Form

 

VAKTRO SCIENTIFIC

Contact us

         195 Panepistimiou str., PC 26443, Patras, Greece
Τ Patras: +30 2610 223999
Τ Athens: +30 210 2751602
     Τ Thessaloniki: +30 2316 019079

Login / Sitemap

© Copyright 2013 - 2024 VAKTRO SCIENTIFIC