Items list
The BFT II Analyzer combines the advantages of mechanical and photo-optical clot-detecting principles by employing a unique turbodensitometric detection device. The semi-automated, dual-channel coagulometer is ideal for low-volume laboratories performing routine coagulation tests.
- Light protection cap reduces the risk of user errors by keeping the pipetting channel closed unless a cuvette has been inserted
- Pre-defined assays with stored reference curves
- Automatic calculation of PT in sec, % of norm, INR, Fibrinogen in mg/dL or g/L
- Dual measuring channels allow for simultaneous determinations
- Half-volume and single cuvette testing require minimal sample volume
- Built-in thermal printer for consolidated result handling
Total efficiency
- Temperature controlled incubation block for reagents and samples
- Sample mixing during measurement
- Automatic result calculation, e.g., PT in sec, % of norm/ PR/ INR, Fibrinogen in mg/dL or g/L
- Stores reference curves
Ease-of-use
- Light protection cap reduces the risk of user errors by keeping the pipetting channel closed unless a cuvette has been inserted
- Built-in timer for incubation
- Membrane keypad for easy handling of test processing
- Pre-programmed methods
Labor and cost savings
- Half-volume and single cuvette testing require minimal sample volume
- Memory function for reference curves
- As a back-up analyzer, the BFT II provides data comparable to those obtained with other Siemens hemostasis analyzers
Assays
PT Reagents
Dade® Innovin® INR
Dade Innovin sec
Dade Innovin %
Thromborel® S INR
Thromborel S sec
Thromborel S %
APTT Reagents
Dade Actin®
Dade Actin FS
Dade Actin FSL
Pathromtin® SL
Fibrinogen Reagents
Multifibren® U
Thrombin Time Reagents
Batroxobin Reagent1
Test Thrombin Reagent1
Thromboclotin®1
Factor Deficient Reagents
Factor II-Dade Innovin1
Factor II-Thromborel S1
Factor V-Dade Innovin1
Factor V-Thromborel S1
Factor VII-Dade Innovin1
Factor VII-Thromborel S1
Factor VIII-Dade Actin1
Factor VIII-Pathromtin SL1
Factor IX-Dade Actin1
Factor IX-Pathromtin SL1
Factor X-Dade Innovin1
Factor X-Thromborel S1
Factor XI-Dade Actin1
Factor XI-Pathromtin SL1
Factor XII-Dade Actin1
Factor XII-Pathromtin SL1
Lupus Anticoagulant Reagents
LA 1 Screening Reagent1
LA 2 Confirmation Reagent1
Thrombosis Risk Reagents
ProC® Globa1
ProC Global FV1
Protein C1
Technical Specifications |
|
Dimensions | Approx. 200 mm x 300 mm x 100 mm (W x D x H) |
Weight | Approx. 3.8 kg |
Onboard Capacity | 4 reagents including 1 reagent mixer |
Incubation block for up to 30 cuvettes | |
Throughput | Approx. 60 PT tests/hour |
Approx. 30 APTT tests/hour | |
Sample Handling | Manual sample pipetting |
Reagent Handling | Manual reagent pipetting |
4 positions GW 15 – bottles | |
GW5 bottles using reducer rings | |
Operation | Pre-programmed methods |
2 free positions for user-defined methods | |
Built-in timer | |